Battery Balance Connection

The BatteryBalanceConnection models lossless energy redistribution between adjacent battery sections within a multi-section battery. It enforces fill ordering (lower sections fill before upper) and handles capacity changes through bidirectional power flow.

Purpose

Multi-section batteries in HAEO separate usable capacity into lower and upper sections. The lower section should fill before the upper section to maximize value from limited cycling capacity. When capacity changes (e.g., due to reserve adjustments), energy may need to redistribute between sections.

The balance connection handles two scenarios:

  1. Downward flow: Energy moves from upper to lower when there is room in the lower section
  2. Upward flow: Energy moves from lower to upper when capacity shrinks below current stored energy

Model formulation

Decision variables

For each time step \(t\):

  • \(P_{\downarrow}(t)\): Power flowing downward from upper to lower (kW, positive)
  • \(P_{\uparrow}(t)\): Power flowing upward from lower to upper (kW, positive)
  • \(S_{\text{unmet}}(t)\): Slack variable for unmet demand (kW)
  • \(S_{\text{absorbed}}(t)\): Slack variable for absorbed excess (kW)

Parameters

  • \(E_{\text{lower}}(t)\): Energy stored in lower section (kWh)
  • \(E_{\text{upper}}(t)\): Energy stored in upper section (kWh)
  • \(C_{\text{lower}}(t)\): Capacity of lower section (kWh, fence-posted T+1 values)
  • \(\Delta t\): Period duration (hours)

Derived quantities:

  • \(\text{demand}(t) = C_{\text{lower}}(t) - E_{\text{lower}}(t)\): Room in lower section
  • \(\text{available}(t) = E_{\text{upper}}(t)\): Energy available in upper section
  • \(\text{excess}(t) = E_{\text{lower}}(t) - C_{\text{lower}}(t+1)\): Energy above next capacity

Constraints

Downward flow

Downward flow implements \(P_{\downarrow} \cdot \Delta t \geq \min(\text{demand}, \text{available})\):

\[ P_{\downarrow}(t) \cdot \Delta t \geq \text{demand}(t) - S_{\text{unmet}}(t) \cdot \Delta t \]
\[ S_{\text{unmet}}(t) \cdot \Delta t \geq \text{demand}(t) - \text{available}(t) \]

The slack variable \(S_{\text{unmet}}\) allows the constraint to handle the case where demand exceeds available energy. A cost penalty on the slack ensures it is minimized.

Upward flow

Upward flow implements \(0 \leq P_{\uparrow} \cdot \Delta t \leq \max(0, \text{excess})\):

\[ P_{\uparrow}(t) \cdot \Delta t \leq \text{excess}(t) + S_{\text{absorbed}}(t) \cdot \Delta t \]
\[ S_{\text{absorbed}}(t) \cdot \Delta t \geq -\text{excess}(t) \]

The slack variable \(S_{\text{absorbed}}\) absorbs negative excess values (when capacity is stable or growing). A cost penalty on the slack ensures it is minimized.

Cost function

The balance connection contributes a cost penalty for slack variables:

\[ \text{Cost} = \sum_{t} \left[ S_{\text{unmet}}(t) + S_{\text{absorbed}}(t) \right] \cdot \Delta t \cdot p_{\text{slack}} \]

where \(p_{\text{slack}}\) is the slack penalty.

The penalty must be larger than typical energy prices to ensure the slack variables are minimized to their theoretical minimum values, correctly implementing the min/max semantics.

Physical interpretation

Lossless transfer: Unlike power connections, balance connections have 100% efficiency. Energy is redistributed within the same physical battery, just between logical sections.

Fill ordering: By requiring downward flow to fill lower section capacity, the model ensures lower sections fill before upper sections. This maximizes value from limited cycling capacity.

Capacity tracking: When battery reserve changes (e.g., user increases reserve during a storm), capacity may shrink. Upward flow handles energy that must vacate the lower section.

Slack penalty selection

The default slack penalty is intentionally large. It must exceed any reasonable energy price to ensure the LP solver minimizes slack variables even when there might be marginal cost benefits to leaving energy unbalanced.

Next steps